Arcus - Mobile DR Solution

Our Digital Mobile X-ray System delivers outstanding performance and space-saving design for mobile imaging providers, as well as exam room and surgery suite applications.

Product Details

The CuattroDR™ touchscreen wireless acquisition tablet can be easily removed, allowing it and the wireless detector to be shared with other portable X-ray devices. They can also be deployed as an in-room imaging solution with permanent X-ray installations. This flexibility makes next day loaner replacement possible (if necessary), substantially reducing down time due to system repairs. This is in contrast to integrated on-board CPU workstations that require on-site technician diagnosis and remotely deployed parts for repair.

  • Constant Potential KW ratings: 20, (32, 40 and 50 available)
  • Kvp Range in 1Kvp Range in 1 KVp steps: 40 to 125 (150 optional)
    Accuracy: +/- (4% + 1mA)
  • Exposure time range: 0.001 - 10 sec.
    Accuracy: +/-(2% +0.1ms)
  • mAs range: 0.1 - 500mAs
  • Operation Independent from mains supply: Standard
  • Collimator: Manual with electronic timer and meter
  • Anatomical programmer: 492 views
  • Automatic exposure control: Optional
  • Connection for Bucky: Optional
  • Remote Wireless: Optional
  • Line voltage range and phases: Single - Phase line automatic regulation from 100 - 240 Vac (+/-10%)
  • Motor Driven Unit: Standard
  • Weight: 541Kg

The CuattroDR™ touchscreen wireless acquisition tablet can be easily removed, allowing it and the wireless detector to be shared with other portable X-ray devices. They can also be deployed as an in-room imaging solution with permanent X-ray installations. This flexibility makes next day loaner replacement possible (if necessary), substantially reducing down time due to system repairs. This is in contrast to integrated on-board CPU workstations that require on-site technician diagnosis and remotely deployed parts for repair.

  • Constant Potential KW ratings: 20, (32, 40 and 50 available)
  • Kvp Range in 1Kvp Range in 1 KVp steps: 40 to 125 (150 optional)
    Accuracy: +/- (4% + 1mA)
  • Exposure time range: 0.001 - 10 sec.
    Accuracy: +/-(2% +0.1ms)
  • mAs range: 0.1 - 500mAs
  • Operation Independent from mains supply: Standard
  • Collimator: Manual with electronic timer and meter
  • Anatomical programmer: 492 views
  • Automatic exposure control: Optional
  • Connection for Bucky: Optional
  • Remote Wireless: Optional
  • Line voltage range and phases: Single - Phase line automatic regulation from 100 - 240 Vac (+/-10%)
  • Motor Driven Unit: Standard
  • Weight: 541Kg