Introducing
ALL-NEW
Cuattro
17 x 34 Long Format (LLI) Detector
Cuattro one m Large Format detector easily accommodates full spine studies on all patients and long leg studies (up to 34”). The one m can also be coupled with qualifying 14 x 17 wireless detectors to provide up to 50” field of view for long leg studies as needed.
See it in Action
Cuattro one m Long Format DR
Under 1 minute
Cuattro one m allows the user to complete Long Format Exams in less than a minute with a single exposure. This results in lower total x-ray dose exposure to patients and staff.
Conventional DR
8-12 minutes
Conventional DR Long Format Exams require up to three separate exposures, increasing patient and staff x-ray dose exposure. Multiple exposures often result in patient motion, necessitating retakes.
Long Format CR
15-25 minutes
Computed Radiography long format studies are time consuming to complete, making patients and physicians wait far too long for study results.

• Cuattro one m easily accommodates full spine studies on all patients and many long leg studies (up to 34”). one m can also be coupled with qualifying 14 x 17 wireless detectors to provide up to 50” field of view for long leg studies as needed.
• A single exposure utilizing the Cuattro one m produces a 17" x 34" field of view (or 17” x 50” when coupled with qualifying detectors).
• Cuattro one m also allows the user to isolate the top or bottom portions of the detector in order to perform 17" x 17" conventional weight bearing studies.
• Cuattro one m can be utilized with an easily removable power and data tether or via battery powered operation with wireless data transfer.
• Optional wireless battery charging is available in select accessories.
• Cuattro one m is able to be retrofitted to existing suites or is available as part of an entirely new, fully featured X-ray suite.
• Both portable and permanent wall stands are available for stationary, mobile, and in suite surgical use.
• Cuattro one m represents a high quality and innovative design from a leading and respected manufacturer at a very attractive price.
Product Details
- Detector Specifications
- Field of View: 17" x 50" *
- Field of View: 17" x 34"
- Field of View: 17" x 17"
- Image Sensor: TFT: a-Si (Amorphous Silicon)
- X-ray Scintillator: Gd2O2S:Tb (Gadolinium Oxysulfide)
- Pixel Pitch: 0.14mm (140 μm)
- Grayscale: 16 bit
- Spatial Resolution: 3.5lp/mm
- X-ray Sync Control: AED (Auto Exposure Detection)
- Dimensions: 900 mm × 465 mm × 17.0 mm
- Weight: 8kg
- Image Transfer:
• Wired: Gigabit Ethernet(1000BASE-T)
• Wireless: IEEE802.11n/ac(2.4GHz/5GHz) - Image Acquisition Time:
• 17" x 50"* detector:
6 second image preview
12 second final image
• 17" x 17" detector:
3.5 second image preview
5.9 second final image - Recommended Cycle Time:
• 17" x 50"* detector: 5.8 seconds
• 17" x 17" detector: 3.7 seconds - OPERATION ENVIRONMENT
Temperature: +10 - +35°C
Humidity: 30 - 85%
(non-condensing)
Shock: 20G
Vibration: 2G - STORAGE/TRANSPORT ENVIRONMENT
Temperature: -15 - +55°C
Humidity: 10 - 90% (non-condensing)
Shock: 25G
Vibration: 5G
* Utilizing a second qualifying overlapped wireless detector
- Active Area: (HxV) 430.08mm x 1290.24mm
- Active Array: 3072 x 9216 pixels
- Effective Area: 428.4mm x 1288.0mm
- Effective Array: 3060 x 9200 pixels
* Utilizing a second qualifying overlapped wireless detector
- Active Area: (HxV) 430.08mm x 860.16mm
- Active Array: 3072 x 6144 pixels
- Effective Area: 428.4mm x 855.4mm
- Effective Array: 3060 x 6110 pixels
- Active Area: (HxV) 430.08mm x 430.08mm
- Active Array: 3072 x 3072 pixels
- Effective Area: 428.4mm x 425.6mm
- Effective Array: 3060 x 3040 pixels
- Image Sensor: TFT: a-Si (Amorphous Silicon)
- X-ray Scintillator: Gd2O2S:Tb (Gadolinium Oxysulfide)
- Pixel Pitch: 0.14mm (140 μm)
- Grayscale: 16 bit
- Spatial Resolution: 3.5lp/mm
- X-ray Sync Control: AED (Auto Exposure Detection)
- Dimensions: 900 mm × 465 mm × 17.0 mm
- Weight: 8kg
- Image Transfer:
• Wired: Gigabit Ethernet(1000BASE-T)
• Wireless: IEEE802.11n/ac(2.4GHz/5GHz) - Image Acquisition Time:
• 17" x 50"* detector:
6 second image preview
12 second final image
• 17" x 17" detector:
3.5 second image preview
5.9 second final image - Recommended Cycle Time:
• 17" x 50"* detector: 5.8 seconds
• 17" x 17" detector: 3.7 seconds - OPERATION ENVIRONMENT
Temperature: +10 - +35°C
Humidity: 30 - 85%
(non-condensing)
Shock: 20G
Vibration: 2G - STORAGE/TRANSPORT ENVIRONMENT
Temperature: -15 - +55°C
Humidity: 10 - 90% (non-condensing)
Shock: 25G
Vibration: 5G
* Utilizing a second qualifying overlapped wireless detector
- Active Area: (HxV) 430.08mm x 1290.24mm
- Active Array: 3072 x 9216 pixels
- Effective Area: 428.4mm x 1288.0mm
- Effective Array: 3060 x 9200 pixels
* Utilizing a second qualifying overlapped wireless detector
- Active Area: (HxV) 430.08mm x 860.16mm
- Active Array: 3072 x 6144 pixels
- Effective Area: 428.4mm x 855.4mm
- Effective Array: 3060 x 6110 pixels
- Active Area: (HxV) 430.08mm x 430.08mm
- Active Array: 3072 x 3072 pixels
- Effective Area: 428.4mm x 425.6mm
- Effective Array: 3060 x 3040 pixels
FOR ANY HELP AND QUERIES
Fill out the form, and we'll get back to you as soon as possible.
Want to leave more info?