Questions? Comments? Contact Us 800.709.4514

Portable DR Solution

Our Digital Portable X-ray System delivers outstanding performance and space-saving design for mobile imaging providers, as well as exam room and surgery suite applications.

Product Details

  • Ultra-portable compact and lightweight design
  • Perfect for mobile services, surgery suites and ambulances
  • High frequency resonant inverter
  • Power: 3.0 kW across full range
  • Input Voltage: 110 - 230 VAC 50/60 Hz
  • kVp Range: 40 - 120 kVp, adjustable in 1 kV increments - Closed loop regulation Power Factor Correction
  • mA Range: Adjustable, 15 mA - 60 mA - closed loop regulation
  • mAs Range: 0.125 - 200
  • Exposure Time: 0.01 - 3.33 seconds
  • Indicators: Digital display of kVp, mAs and Exposure Time X-ray, Ready, mA Station and Fault indicators
  • Filtration: 4.3 mm aluminium @ 120kVp
  • Exposure Switch: Detachable two-position
  • Stationary Anode 130 kVp
  • Target Material: Tungsten
  • Anode Capacity: 45,000 HU Storage
  • Focal Spot: 1.2 mm
  • Target Angle: 15°
  • Collimare CP-100-24-C
  • Laser Crosshairs: Center Locator
  • Tape Measure: SID Measurement
  • Inclinometer: Angle Measurement
  • Min. F/S to Floor: 13” / 33 cm
  • Max. F/S to Floor: 78” / 198 cm
  • Hor. Ext. of F/S: 21” / 53 cm
  • Hor. Rotation: 200°
  • Tube Rotation: 270°
  • Operation Mode: 26"W x 42"L x 53"H
  • Storage Mode: 26"W x 53"Lx 28"H
  • Wheels:16" Inflatable Heavy Duty Casters
  • 110 lbs. / 50 kg
  • Ultra-portable compact and lightweight design
  • Perfect for mobile services, surgery suites and ambulances
  • High frequency resonant inverter
  • Power: 3.0 kW across full range
  • Input Voltage: 110 - 230 VAC 50/60 Hz
  • kVp Range: 40 - 120 kVp, adjustable in 1 kV increments - Closed loop regulation Power Factor Correction
  • mA Range: Adjustable, 15 mA - 60 mA - closed loop regulation
  • mAs Range: 0.125 - 200
  • Exposure Time: 0.01 - 3.33 seconds
  • Indicators: Digital display of kVp, mAs and Exposure Time X-ray, Ready, mA Station and Fault indicators
  • Filtration: 4.3 mm aluminium @ 120kVp
  • Exposure Switch: Detachable two-position
  • Stationary Anode 130 kVp
  • Target Material: Tungsten
  • Anode Capacity: 45,000 HU Storage
  • Focal Spot: 1.2 mm
  • Target Angle: 15°
  • Collimare CP-100-24-C
  • Laser Crosshairs: Center Locator
  • Tape Measure: SID Measurement
  • Inclinometer: Angle Measurement
  • Min. F/S to Floor: 13” / 33 cm
  • Max. F/S to Floor: 78” / 198 cm
  • Hor. Ext. of F/S: 21” / 53 cm
  • Hor. Rotation: 200°
  • Tube Rotation: 270°
  • Operation Mode: 26"W x 42"L x 53"H
  • Storage Mode: 26"W x 53"Lx 28"H
  • Wheels:16" Inflatable Heavy Duty Casters
  • 110 lbs. / 50 kg